Introduction:
To ensure the quality of pharmaceutical products, stability testing must be conducted to estimate their shelf life and storage conditions. Stability testing primarily investigates the impact of environmental factors such as temperature, humidity, and light on the quality of pharmaceuticals over time. By studying the degradation curve of the product, the effective shelf life can be determined, ensuring the efficacy and safety of the drug during its use.
Test Type |
Storage Conditions(Note 2) |
Long-term Testing |
25°C ± 2°C / 60% ± 5% RH or 30°C ± 2°C / 65% ± 5% RH |
Accelerated Testing |
40°C ± 2°C / 75% ± 5% RH |
Intermediate Testing (Note 1) |
30°C ± 2°C / 65% ± 5% RH |
Note 1: If the long-term testing condition is already set at 30°C ± 2°C / 65% ± 5% RH, intermediate testing is not required. However, if the long-term condition is 25°C ± 2°C / 60% ± 5% RH and significant changes are observed during accelerated testing, intermediate testing should be added. The evaluation should be based on the criteria for "significant changes."
Test Type |
Storage Conditions |
Long-term Testing |
5°C ± 3°C |
Accelerated Testing |
25°C ± 2°C / 60% ± 5% RH |
Test Type |
Storage Conditions |
Long-term Testing |
-20°C ± 5°C |
Accelerated Testing |
5°C ± 3°C |
For formulations containing water or solvents that may experience solvent loss, stability testing should be conducted under low relative humidity (RH) conditions when stored in semi-permeable containers. Long-term or intermediate testing should be performed for 12 months, and accelerated testing for 6 months, to demonstrate that the product can withstand low RH environments.
Test Type |
Storage Conditions |
Long-term Testing |
25°C ± 2°C / 40% ± 5% RH or 30°C ± 2°C / 35% ± 5% RH |
Accelerated Testing |
40°C ± 2°C / ≤25% RH |
Intermediate Testing (Note 1) |
30°C ± 2°C / 35% ± 5% RH |
Note 1: If the long-term testing condition is set at 30°C ± 2°C / 35% ± 5% RH, intermediate testing is not required.
The following table provides the water loss rate ratio at 40°C under different relative humidity conditions:
Substitute RH (A) |
Reference RH (R) |
Water Loss Rate Ratio ([1-R]/[1-A]) |
60% RH |
25% RH |
1.9 |
60% RH |
40% RH |
1.5 |
65% RH |
35% RH |
1.9 |
75% RH |
25% RH |
3.0 |
Explanation: For aqueous pharmaceuticals stored in semi-permeable containers, the water loss rate at 25% RH is three times that at 75% RH.
This document provides a comprehensive framework for conducting stability testing under various storage conditions to ensure the quality, efficacy, and safety of pharmaceutical products throughout their shelf life.
These experiments can be achieved through our high and low temperature humid heat test chamber, more customized requirements please contact us.