bandera
Hogar blog

IEC-60068-2 Combined Test of Condensation and Temperature and Humidity

IEC-60068-2 Combined Test of Condensation and Temperature and Humidity

October 14, 2024

IEC-60068-2 Combined Test of Condensation and Temperature and Humidity

Difference of IEC60068-2 damp heat test specifications

In the IEC60068-2 specification, there are a total of five kinds of humid heat tests, in addition to the common 85℃/85%R.H., 40℃/93%R.H. In addition to fixed-point high temperature and high humidity, there are two more special tests [IEC60068-2-30, IEC60068-2-38], these two are alternating wet and humid cycle and temperature and humidity combined cycle, so the test process will change temperature and humidity, and even multiple groups of program links and cycles, applied in IC semiconductors, parts, equipment, etc. To simulate the outdoor condensation phenomenon, evaluate the material's ability to prevent water and gas diffusion, and accelerate the product's tolerance to deterioration, the five specifications were organized into a comparison table of the differences in the wet and heat test specifications, and the test points were explained in detail for the wet and heat combined cycle test, and the test conditions and points of GJB in the wet and heat test were supplemented.

IEC60068-2-30 alternating humid heat cycle test

This test uses the test technique of maintaining humidity and temperature alternating to make moisture penetrate into the sample and cause condensation (condensation) on the surface of the product to be tested, so as to confirm the adaptability of the component, equipment or other products in use, transportation and storage under the combination of high humidity and temperature and humidity cyclic changes. This specification is also suitable for large test samples. If the equipment and the test process need to keep the power heating components for this test, the effect will be better than IEC60068-2-38, the high temperature used in this test has two (40 ° C, 55 ° C), the 40 ° C is to meet most of the world's high temperature environment, while 55 ° C meets all the world's high temperature environment, the test conditions are also divided into [cycle 1, cycle 2], In terms of severity, [Cycle 1] is higher than [Cycle 2].

Suitable for side products: components, equipment, various types of products to be tested

Test environment: the combination of high humidity and temperature cyclic changes produces condensation, and three kinds of environments can be tested [use, storage, transportation ([packaging is optional)]

Test stress: Breathing causes water vapor to invade

Whether power is available: Yes

Not suitable for: parts that are too light and too small

Test process and post-test inspection and observation: check the electrical changes after moisture [do not take out the intermediate inspection]

Test conditions: Humidity: 95%R.H.[Temperature change after high humidity maintenance](low temperature 25±3℃←→ high temperature 40℃ or 55℃)

Rising and cooling rate: heating (0.14℃/min), cooling (0.08 ~ 0.16℃/min)

Cycle 1: Where absorption and respiratory effects are important features, the test sample is more complex [humidity not less than 90%R.H.]

Cycle 2: In the case of less obvious absorption and respiratory effects, the test sample is simpler [humidity is not less than 80%R.H.]

Temperature Cycling Test Chamber

IEC60068-2 damp heat test specification difference comparison table

For component type parts products, a combination test method is used to accelerate the confirmation of the test sample's resistance to degradation under high temperature, high humidity and low temperature conditions. This test method is different from the product defects caused by respiration [dew, moisture absorption] of IEC60068-2-30. The severity of this test is higher than that of other humid heat cycle tests, because there are more temperature changes and [respiration] during the test, the cycle temperature range is larger [from 55℃ to 65℃], and the temperature change rate of the temperature cycle is faster [temperature rise: 0.14 ° C /min becomes 0.38 ° C /min, 0.08 ° C /min becomes 1.16 ° C /min], in addition, different from the general humid heat cycle, the low temperature cycle condition of -10 ° C is added to accelerate the breathing rate and make the water condensed in the gap of the substitute freeze, which is the characteristic of this test specification. The test process allows the power test and the applied load power test, but it can not affect the test conditions (temperature and humidity fluctuation, rising and cooling rate) because of the heating of the side product after power. Due to the change of temperature and humidity during the test process, there can not be condensation water droplets on the top of the test chamber to the side product.

Suitable for side products: components, metal components sealing, lead end sealing

Test environment: combination of high temperature, high humidity and low temperature conditions

Test stress: accelerated breathing + frozen water

Whether it can be powered on: it can be powered on and external electric load (it can not affect the conditions of the test chamber because of power heating)

Not applicable: Can not replace moist heat and alternating humid heat, this test is used to produce defects different from respiration

Test process and post-test inspection and observation: check the electrical changes after moisture [check under high humidity conditions and take out after test]

Test conditions: damp heat cycle (25 please - 65 + 2 ℃ / 93 + / - 3% R.H.) please - low temperature cycle (25 please - 65 + 2 ℃ / 93 + 3% R.H. - - 10 + 2 ℃) X5cycle = 10 cycle

Rising and cooling rate: heating (0.38℃/min), cooling (1.16 ℃/min)

Heat and humidity cycle (25←→65±2℃/93±3%R.H.)

Low temperature cycle (25←→65±2℃/93±3%R.H. →-10±2℃)

GJB150-09 damp heat test

Instructions: The wet and heat test of GJB150-09 is to confirm the ability of equipment to withstand the influence of hot and humid atmosphere, suitable for equipment stored and used in hot and humid environments, equipment prone to high humidity, or equipment that may have potential problems related to heat and humidity. Hot and humid locations can occur throughout the year in the tropics, seasonally in mid-latitudes, and in equipment subjected to combined pressure, temperature and humidity changes, with special emphasis on 60 ° C /95%R.H. This high temperature and humidity does not occur in nature, nor does it simulate the dampness and heat effect after solar radiation, but it can find the parts of the equipment with potential problems, but it cannot reproduce the complex temperature and humidity environment, evaluate the long-term effect, and can not reproduce the humidity impact related to the low humidity environment.

Relevant equipment for condensation, wet freezing, wet heat combined cycle test: constant temperature and humidity test chamber

Constant Temperature Test Chamber

dejar un mensaje

dejar un mensaje
Si está interesado en nuestros productos y desea conocer más detalles, deje un mensaje aquí, le responderemos lo antes posible.
entregar

Hogar

Productos

Whatsapp

contáctanos